Comparison of Metascreen Testing Platforms

ParameterGC/MSMS/MS
Sampling Urine:
  • Contains more than 3,000 detectable metabolites, with many in higher concentration than in blood
  • Non-invasive, safe, and simple for collection by parents or hospital staff
Blood:
  • Though contains similar number of detectable metabolites as urine, many not in as high concentration than in urine
  • Invasive, painful, requires technical expertise, risk of infection
  • Certain metabolic disoreders do not alter blood amino acid or acylcarnitine profile, hence further testing is required to differentiate type o disorder
No. of IEMs that can be detected and quantified 100+ IEMs from 9 groups of IEMs
  • Amino acidemia
  • Organic acidemia
  • Fatty acid disorders
  • Sugar disorders
  • Urea cycle disorders
  • Lactate, pyruvate + TCA cycle abnornalities
  • Urea cycle disorders
  • Purine, pyrimidine disorders
  • Peroxisomal disorders
40+ IEMs from 3 groups of IEMs
  • Amino acidemia
  • Organic acidemia
  • Fatty acid disorders
Biomarker i.e. no. of analyte profiles used Multiple markers used:
Highly specific, definitive interpretation from one single test
Mostly single marker used:
Non-specific, ambiguous – 2nd tier testing required
Time to diagnosis Faster:
From screening cum confirmation to diagnosis
Slower:
From screening to confirmation then finally to diagnosis
Further confirmation required Screening and confirmation from one single test, though occasionally requires further confirmation via:
  • Enzyme assays
  • Genetic testing
Requires confirmatory test via:
  • GC/MS
  • Enzyme assays
  • Genetic testing
Throughput Approximately 15 minutes per sample:
Total throughput of about 60 – 90 samples per machine in one day
Approximately 2 minutes per sample:
Total throughput of about 500 samples per machine in one day thus better for mass screening
Interference
  • Chromatography separates potential interfering compounds, such as drugs and exogenous chemicals
  • Acylcarnitine profiling not critical in GC/MS urinary analysis
Certain drugs and exogenous chemicals can interfere with acylcarnitine profile analysis e.g. valproic acid, cefotaxime, dextrose